Spezielle Tastenkombinationen auf BHT-Scannern: Unterschied zwischen den Versionen
Aus GEVITAS
Zeile 100: | Zeile 100: | ||
|LCD/beeper/Vibration adjustment | |LCD/beeper/Vibration adjustment | ||
|M1+PW at same time F5/F6 for up down F7/F8 for adjustment | |M1+PW at same time F5/F6 for up down F7/F8 for adjustment | ||
+ | |- | ||
+ | |'''BHT-805-B''' | ||
+ | | | ||
+ | |- | ||
+ | |Aktuelles Programm neu starten (z.B. nach Error 0005) | ||
+ | |Ausschalten. Taste '''ENT''' drücken und festhalten, dann einschalten. | ||
|} | |} | ||
Aktuelle Version vom 17. November 2015, 10:41 Uhr
Die Scanner der BHT-Serie haben bestimmte Tastenkombinationen für spezielle Funktion. Hier ein Überblick:
Modell/Funktion | Drücke... |
---|---|
BHT-2000 | |
Initialize | Trigger+SF+0+PW at same time |
System menu | SF+1+PW at same time |
LCD beeper adjustment | M1+PW at same time F5/F6 for up down F7/F8 for adjustment |
Memory test | System Menu >5 ( Set System ) >6 ( Switch ) >SF+0 at same time |
BHT-3000 | |
Initialize | Trigger+SF+0+PW at same time |
System menu | SF+1+PW at same time |
LCD+beeper adjustment | Trigger+PW at same time |
BHT-4000 | |
System download | Trigger+C+F1+PW at same time |
System download/RF subsystem | in RF menu press SF+0 |
Initialize | Trigger+SF+0+PW at same time |
System menu | SF+1+PW at same time |
LCD+beeper adjustment | Trigger+PW at same time |
BHT-5000 | |
System download | Trigger+M2+ENT+PW at same time |
Initialize | Trigger+SF+0+PW at same time |
System menu | SF+1+PW at same time |
LCD+beeper adjustment | Trigger+PW at same time |
BHT-6000 | |
System download | M1+M2+ENT+PW at same time |
Initialize | SF+M1+0+PW at same time |
System menu | SF+1+PW at same time |
LCD+beeper adjustment | M1+PW at same time F5/F6 for up down F7/F8 for adjustment |
Kanji fonts | SF+2 at same time in system menu |
BHT-7000/7500/100 | |
System download | M1+M2+ENT+PW at same time |
Initialize | SF+M1+0+PW at same time |
All User area | SF+2 at the same time |
System menu | SF+1+PW at same time |
LCD/beeper/Vibration adjustment | M1+PW at same time F5/F6 for up down F7/F8 for adjustment |
BHT-805-B | |
Aktuelles Programm neu starten (z.B. nach Error 0005) | Ausschalten. Taste ENT drücken und festhalten, dann einschalten. |